<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>bay</ParameterFamily>
<LongName>
rotate_plate
</LongName>
<Name>
rp
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
The rotate_plate parameter is used to selectively enable the plate rotator.
</text></DescriptionText>
<DescriptionText><text>
This state parameter is not normally modified with the 'set' command. The
firmware uses this parameter for internal 'housekeeping'.
</text></DescriptionText>
<DescriptionText><text>
Print Console V2.0 or higher:
</text></DescriptionText>
<DescriptionText><text>
This parameter will be updated as part of the load bay command.  It should NOT be
set manually.
</text></DescriptionText>
<DescriptionText><text>
If this parameter is set to 0, then the plate will NOT be rotated before being fed
into the processor.
</text></DescriptionText>
<DescriptionText><text>
If this parameter is set to 1, then the plate WILL be rotated 90 degrees before being
fed into the processor.
</text></DescriptionText>
<DescriptionText><text>
Allegro workstation software:
</text></DescriptionText>
<DescriptionText><text>
This parameter must be set through diagnostics, and that setting will be used on all plates.
</text></DescriptionText>
<DescriptionText><text>
If this parameter is set to 0, then the plate will NOT be rotated before being
fed into the processor.
</text></DescriptionText>
<DescriptionText><text>
As of firmware V1.40:
</text></DescriptionText>
<DescriptionText><text>
If this parameter is set to 1, then the firmware will always present the shortest
edge to the processor.  Plates loaded in portrait will not be rotated; plates loaded
in landscape will be rotated 90 degrees prior to being fed into the processor.
</text></DescriptionText>
<DescriptionText><text>
If this parameter is set to 2, then ALL plates will be rotated 90 degrees prior to
being fed into the processor.
</text></DescriptionText>
<DescriptionText><text>
Prior to firmware V1.40:
</text></DescriptionText>
<DescriptionText><text>
If this parameter is set to 1, then the plate WILL be rotated 90 degrees before being
fed into the processor.
</text></DescriptionText>
</Description>
<Type>
uint8
</Type>
<Default>
<UnnumberedList>
<li>1</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 2</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
This parameter will automatically be copied into "state plate_loc" when a plate is picked.
</text></DescriptionText>
</Notes>
<Partition>
state
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/al_cfg_ri.xml</LinkAddress><LinkTitle>NVS: al ri</LinkTitle></Link></li>
<li><Link><LinkAddress>../nvs/plate_loc_state_rp.xml</LinkAddress><LinkTitle>NVS: plate_loc rp</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>